4,213 research outputs found

    Magnetic nanoparticle density mapping from the magnetically induced displacement data: a simulation study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Magnetic nanoparticles are gaining great roles in biomedical applications as targeted drug delivery agents or targeted imaging contrast agents. In the magnetic nanoparticle applications, quantification of the nanoparticle density deposited in a specified region is of great importance for evaluating the delivery of the drugs or the contrast agents to the targeted tissues. We introduce a method for estimating the nanoparticle density from the displacement of tissues caused by the external magnetic field.</p> <p>Methods</p> <p>We can exert magnetic force to the magnetic nanoparticles residing in a living subject by applying magnetic gradient field to them. The nanoparticles under the external magnetic field then exert force to the nearby tissues causing displacement of the tissues. The displacement field induced by the nanoparticles under the external magnetic field is governed by the Navier's equation. We use an approximation method to get the inverse solution of the Navier's equation which represents the magnetic nanoparticle density map when the magnetic nanoparticles are mechanically coupled with the surrounding tissues. To produce the external magnetic field inside a living subject, we propose a coil configuration, the Helmholtz and Maxwell coil pair, that is capable of generating uniform magnetic gradient field. We have estimated the coil currents that can induce measurable displacement in soft tissues through finite element method (FEM) analysis.</p> <p>Results</p> <p>From the displacement data obtained from FEM analysis of a soft-tissue-mimicking phantom, we have calculated nanoparticle density maps. We obtained the magnetic nanoparticle density maps by approximating the Navier's equation to the Laplacian of the displacement field. The calculated density maps match well to the original density maps, but with some halo artifacts around the high density area. To induce measurable displacement in the living tissues with the proposed coil configuration, we need to apply the coil currents as big as 10<sup>4</sup>A.</p> <p>Conclusions</p> <p>We can obtain magnetic nanoparticle maps from the magnetically induced displacement data by approximating the Navier's equation under the assumption of uniform-gradient of the external magnetic field. However, developing a coil driving system with the capacity of up to 10<sup>4</sup>A should be a great technical challenge.</p

    Use of smartphones by art and design students for accessing library services and learning

    Get PDF
    Purpose – The purpose of this paper is to explore art and design students’ use of smartphones for accessing library services and learning at the Hong Kong Design Institute (HKDI). Design/methodology/approach – A questionnaire survey involving 51 HKDI students was conducted to examine the students’ utilization of apps and the internet on mobile devices to find information for the purpose of academic learning, social networking, and collaborative learning. Findings – Survey results showed that while the HKDI students were all smartphone owners and active users of such mobile communication devices, only a minority of them “frequently” use these mobile devices for formal learning purposes. They demonstrated a keen preference to use search engines, social communications, and other diverse use of smartphones. Except for research and image/audio-visual needs, the rest of their needs and usage behaviour is similar to mainstream university students. Practical implications – The results suggest opportunities for the libraries to develop services and facilities that could better fulfil students’ information needs, and to improve the network coverage outside the library. Originality/value – This is probably the first study of its kind to explore art and design students’ use of smartphones for learning needs. In particular, the recent capability of smartphones and mobile internet speed are comparable with desktops, it is vital to re-examine the much changed environment and user needs.postprin

    How can the R.E.N.A.L. nephrometry scoring system aid management of a solid renal mass?

    Get PDF
    OBJECTIVES. To investigate use of the R.E.N.A.L. nephrometry score in relation to the choice of treatment and postoperative complications for renal masses. DESIGN. Case series. SETTING. A tertiary referral hospital in Hong Kong. PATIENTS. Data of patients undergoing nephrectomy were collected retrospectively from a clinical database and analysed. A R.E.N.A.L. nephrometry score was allocated to each renal tumour by a blinded qualified radiologist, utilising computerised imaging systems. Patient demographics, choice of surgery (radical vs partial), and approaches (open vs minimally invasive) were analysed with respect to their R.E.N.A.L. score. RESULTS. In all, 74 patients were included during the study period, of which 38 underwent partial nephrectomy and 36 underwent radical nephrectomy. No differences between the groups were found with respect to patient demographics. There were significant differences between the partial and radical nephrectomy groups in terms of their mean nephrometry score (6.9 vs 9.3, P<0.001). The mean nephrometry sum was also significantly different in the open approach versus the minimally invasive approach in patients having partial nephrectomy (7.8 vs 6.0, P=0.001). There was no difference in the postoperative 90-day morbidity and mortality in the partial nephrectomy and radical nephrectomy groups. CONCLUSIONS. The R.E.N.A.L. nephrometry score of a renal mass correlated significantly with our choice of surgery (partial vs radical) and our approach to surgery (open vs minimally invasive surgery), particularly in the partial nephrectomy group. It does not, however, correlate with postoperative complications. The nephrometry score provides a useful tool for objectively describing renal mass characteristics and enhancing better communication for the operative planning directed at renal masses.published_or_final_versio

    Spatial resolution study and power calibration of the high-k scattering system on NSTX

    Get PDF
    NSTX high-k scattering system has been extensively utilized in studying the microturbulence and coherent waves. An absolute calibration of the scattering system was performed employing a new millimeter-wave source and calibrated attenuators. One of the key parameters essential for the calibration of the multichannel scattering system is the interaction length. This interaction length is significantly different from the conventional one due to the curvature and magnetic shear effect.ope

    Effect of surfactant concentration variation on the thermoelectric properties of mesoporous ZnO

    Get PDF
    The electrical and thermal conductivities and the Seebeck coefficient of mesoporous ZnO thin films were investigated to determine the change of their thermoelectric properties by controlling surfactant concentration in the mesoporous ZnO films, because the thermoelectric properties of mesoporous ZnO films can be influenced by the porosity of the mesoporous structures, which is primarily determined by surfactant concentration in the films. Mesoporous ZnO thin films were successfully synthesized by using sol-gel and evaporation-induced self-assembly processes. Zinc acetate dihydrate and Brij-76 were used as the starting material and pore structure-forming template, respectively. The porosity of mesoporous ZnO thin films increased from 29% to 40% with increasing surfactant molar ratio. Porosity can be easily altered by controlling the molar ratio of surfactant/precursor. The electrical and thermal conductivity and Seebeck coefficients showed a close correlation with the porosity of the films, indicating that the thermoelectric properties of thin films can be changed by altering their porosity. Mesoporous ZnO thin films with the highest porosity had the best thermoelectric properties (the lowest thermal conductivity and the highest Seebeck coefficient) of the films examined. © 2013 Min-Hee Hong et al

    Proactive Maintenance Strategy Based on Resilience Empowerment for Complex Buildings

    Get PDF
    Resilience of the built environment, particularly in complex buildings, is strictly related to the effectiveness of systems and sub-systems that provide the expected features to manage risk scenarios in routine and non-routine conditions. In this perspective, maintenance is therefore a key factor to assure building resilience by keeping systems and equipment in the required operational state. Risk management can be empowered if system resilience and disruptive events are monitored in real-time, and, to this aim, proactive maintenance can nowadays monitor systems resilience with innovative digital tools

    Toxicity assessment of modified Cry1Ac1 proteins and genetically modified insect-resistant Agb0101 rice

    Get PDF
    Insect-resistant Agb0101 rice was recently developed by modifying the cry1ac1 gene by changing codon usage changes relative to the native truncated cry1ac1 gene. To assess the toxicity of genetically modified Agb0101 rice, we conducted bioinfomational comparisons of the amino acid sequences that are not similar to known toxic proteins. Sufficient quantities of mCry1Ac1 protein were produced in Escherichia coli for in vitro evaluation and animal study. We compared the amino acid sequences and molecular mass. There have the same amino acid sequences and molecular masses after purifying the modified Cry1Ac1 (mCry1Ac1) protein from highly expressed bacteria and genetically modified rice were identical. We also investigated the acute and 90-days oral toxicities. No adverse effects were observed in mice following acute oral exposure to 2,000 mg/ kg body weight mCry1Ac1 protein of body weight and 90 days oral exposure to Agb0101. These results indicate that mCry1Ac1 proteins and Agb0101 rice demonstrate no adverse effects in these tests when applied via gavage and feed, respectively.Key words: Modified Cry1Ac1, food safety assessment, toxicity, insect- resistant rice Agb0101
    corecore